Viztek Compact DR system: is an integrated system for all conventional radiographic applications in combination with a High Frequency Generator, makes the Compact the most advanced system available.The system has been designed focusing on flexibility and user friendliness. It can be further configured depending on your exact clinical requirements.
Configuration:
- Floor Mount 8' 6"
- H.T. cables
- Manual Collimator
- Gadolinium Detector Technology - 17" x 17" Active Imaging Area
- X-Ray Generator SHF525 50KW, 150KV, Three phase
- X-Ray Tube E7242X 125Kvp 200,000 HU, .6 - 1.5 focal spot
Mechanical Swivel Arm with Flat Panel Cabinet
- Floor-to-wall mounted support
- Electromagnetic brakes for all movements
Mechanical Movements:
- Variable SID distance, adjustable between 39.4 to 70.9".
- Swivel arm range of rotation: 135°, with detents on -30°, 0°, 90°, 120°.
- Swivel arm vertical movement: 39".
- Minimum floor to detector center distance: 27.6'
- Detector Angulations: +45/-45°
- Electromagnetic brakes for all movements
- Adaptation for flat panel cabinet.
- Dimensions (H x W x D): 8' 9" x 7'4" x 4'6".
Manual Collimator
- Manual collimator with 6 pair of blades
- Accessory rails (cones, filters, etc)
- Field light lamp (light of the lamp 160 lux)
- Light indicator for alignment with the bucky
- Lamp timing
- Retractable measuring tape
High Tension Cables
- (2) 9 meters Ultra Flexible High Tension Cables, 75 kVp
High/Low Starter (3000/10,000 RPM) for one X-Ray tube: High-speed starter for anode rotation of one x-ray tube of equal or different impedance.
- Rotation control of the anode at low speed: 3.000 R.P.M., (60Hz) in
function of the selected power
- Rotation control of the anode at low speed: 10.000 R.P.M., (180z) in
function of the selected power
- Anode Rotation Brake control
- Time delay of the brake in function of the sequence of exposure selected
SHF410 40kW Generator Features:
- High Frequency 25KHz, 1 tube operation
- Microprocessor controlled with auto diagnostic and error code indication
for easy maintenance
- Single phase 208/240 VAC (specify prior to order)
- Output power:
500 mA @ 80kVp
300mA @ 100kVp
320 mA @ 125 kVp
- Automatic line compensation +/-10%
- Microprocessor controlled
- X-ray tube overload protection
- X-ray tube H.U. available indication and continuous monitoring for x-ray
tube protection
- Control of x-ray tube number of exposures
- Hand switch for preparation and exposure control
- Light and sound indication for x-ray exposure
- kVp Radiographic range, from 40 to 125 kVp in 1 kVp step
- mA Radiographic range from 10 to 500mA in 18 step, Renard scale 10,
12.5, 16, 20, 25, 32, 40, 50, 64, 80, 100, 125, 160, 200, 250, 320, 400,
500
- mAs range from 0.1 to 500 mAs in 38 steps, Renard scale
- Exposure time range from 1 ms to 10 seconds, 41 Time Stations
X-Ray Tube, Toshiba Model E7242X
- Maximum Tension, 125 kVp
- Focus sizes:
-- Small focus 0.6 mm (0.023")
-- Large focus 1.5 mm (0.047")
- Maximum power:
-- Small focus 18 KW
-- Large focus 50 KW
- Maximum Current
-- Small focus 290 mA
-- Large focus 800 mA
- Anode degree target angle 14 degrees
- Anode heat capacity 200,000 HU
- Anode rotation 2,700/3,200 RPM
- Anode composition Rhenium, Tungsten and face Molybdenum
- Anode diameter 2.9"
- Filtration equivalent 0.7" AL
High Resolution Digital Radiography System, including:
Flat Panel Detector Assembly
- Vizion DR Gadolinium Detector
- Detector Housing
- Grid, High density, stationary, removable (10:1)
- 17"x17" active imaging area with Off Center Imaging
- Pixel size 143m
- Pixel Array - 3072 x 3072
- A/D Conversion - 14 bits
Adaptation Kit for Vizion 17"x17" Flat Panel Detector
In-room rack
- Workstation power supply
- FDP power supply with special control
- Generator Interface Board
System Computer
DELL COMPATIBLE TOWER WORKSTATION(T1600)
- I3 PROCESSOR, 4 GB RAM
- RAID 1 - 1 TB (2 X 1TB HDD)
- INTEGRATED GIGABIT NIC, KEYBOARD AND MOUSE, 500R UPS
DICOM Print, Store and MWL HIS/RIS
Display Monitor:
- SINGLE 1.3MP 19" LCD MONITOR
- RESOLUTION 1280 X 1024
- 8000:1 Ratio
Cables
Acquisition workflow management
- Automatic setting of acquisition parameters according to body part and
system specific programmable APRs (Anatomically Programmed
Radiography)
- One console operation - generator parameters setting by the workstation
as part of APR
- Patient data entry, manually or automatically from the DICOM worklist
(MWL optional)
- Urgent patient registration
- Preview image typically within 4-5 seconds after exposure
- Exam specific image processing for optimized image quality
- Automatic backup of operator accepted images.
Review & Processing
- Patient review
- Window/Level
- Reverse Black/White (Window polarity inversion)
- Image rotation
- Electronic zoom with pan & scroll capabilities
- Magnifying glass
- Multi-scale contrast enhancement and Dynamic Range
- Electronic shutter for masking of image (cropping)
- Multiformat display (for printing)
- Screen display formats of 1,2,4,6 within a single frame
- Automatic background filming
- Optimized image processing parameters
| Manufacturer | Viztek |
|---|---|
| Generator Type | No |
| Type of System | Full DR Room |
| Generator Output (in Kilowatts) | No |